Industrial chiller uses:
It should be used for cooling molds, pipelines, and pools to improve the surface finish of plastic products and reduce marks, so that the products will not shrink or deform, and will be easy to demould. It facilitates the demoulding of plastic products and accelerates product shaping, thus greatly improving the production efficiency of plastic molding machines.
Industrial chiller uses:
It should be used for cooling molds, pipelines, and pools to improve the surface finish of plastic products and reduce marks, so that the products will not shrink or deform, and will be easy to demould. It facilitates the demoulding of plastic products and accelerates product shaping, thus greatly improving the production efficiency of plastic molding machines.
Application industry
Injection molding, extrusion, bottle blowing, machining, casting, surface treatment, laser technology, welding, plastic molding, electronics, electroplating, pharmaceutical chemicals, printing and other industries.
Features of air-cooled chiller:
1.The advantages of the air-cooled chiller are: it absorbs cold air by itself and discharges hot air for heat dissipation. It does not require an external cooling tower, has no restrictions on circulating water pipelines, and is easy to install and move.
2.No need to install a cooling water tower, easy to install and move, suitable for places where water sources are lacking and no need to install a water tower.
3.Low-noise fan motor, excellent cooling and condensation effect, stable throttling mechanism, excellent anti-rust treatment.
4.Using high-performance compressors imported from Europe and the United States, with high EER value, low noise and stable operation. This product adopts a touch-type waterproof and dustproof control panel, and the cooling temperature is adjustable from 3 to 30°C. The contactor belongs to the French Schneider series. The control system adopts a modular design and is equipped with multiple protection devices such as acid and alkali protection, current overload protection, high and low voltage protection, and time delay protection. If there is a fault, it will alarm and display the fault in time.
5.This product uses a brand new imported compressor, which belongs to Japan's Sanyo Panasonic series, making the product more energy efficient. The condenser adopts a vertical shell-and-tube design, and the evaporator copper tube adopts high-efficiency internally threaded copper tube, which can effectively improve the thermal effect and is easy to clean.
Application industries
Plastics (injection molding, extrusion, bottle blowing industry), plastic packaging industry, automobile manufacturing industry, laser welding, electronic manufacturing, electroplating, pharmaceutical and chemical industry, ultrasonic cooling, printing and other industries, production maintains stable operating temperature of equipment and processes
2 regular models
How to choose a chiller?
Comes with a built-in fan to dissipate heat from the chiller, suitable for environments with good ventilation
An additional cooling tower is required to dissipate heat from the condenser
Three evaporator modes
Suitable for different refrigeration purposes of equipment
It comes with a water tank, which can be connected to tap water and used for closed cooling.
Example: cooling injection molding machine, laser machine, printing machine, etc.....
It is suitable for use in open water tanks, similar to water tanks, for pool cooling.
Example: cooling extruder water tank, cooling pool, etc.....
It is made of stainless steel and is designed for use in open cooling systems that require water quality.
Example: food grade equipment, drinking water cooling, etc...
Detailed description
High-quality accessories achieve higher quality
Actual picture of air-cooled chiller
5HP-200HP models are available
Use the installation simple diagram reference
Technical Parameters
Model | GX-3FWS | GX-5FWS | GX-8FWS | GX-10FWS | GX-15FWS | GX-20FWS | GX-30FWS | GX-40FWS | GX-50FWS | |||
Refrigerating capacity | W | 9000 | 15000 | 24000 | 3000 | 45000 | 60000 | 90000 | 12000 | 12000 | ||
Compressor power | KW | 2.2 | 3.7 | 6 | 7.5 | 11 | 15 | 22 | 30 | 30 | ||
Frozen warer pump power | HP | 0.5 | 0.5 | 1 | 1 | 2 | 3 | 3HP | 5HP | 5HP | ||
Cooiling warer fiow | L/min | 100 | 100 | 200 | 200 | 340 | 520 | 520 | 800 | 800 | ||
Water pump head | m | 18 | 18 | 18 | 18 | 18 | 18 | 20 | 20 | 20 | ||
Chilled water pipe | 寸 | 1 | 1 | 1 | 1.5 | 2 | 2 | 2.5 | 2.5 | 2.5 | ||
Tank capacity | L | 54 | 54 | 156 | 156 | 180 | 260 | 280 | 460 | 580 | ||
Cooling fan | MM | 350*2 | 400*2 | 450*2 | 450*2 | 600*2 | 550*3 | 630*3 | 600*4 | 630*4 | ||
Net weight | Kg | 160 | 190 | 310 | 350 | 520 | 630 | 840 | 1140 | 1500 | ||
Outline dimensions | L*W*H(mm) | 110*500*990 | 120*500*1060 | 1450*700*1500 | 1450*700*1500 | 1750*900*1600 | 2000*900*1750 | 2200*930*1750 | 2200*1760*1980 | 2500*1900*2100 | ||
lnput power | 3P-380V( 415-50HZ / 60HZ ; 3PH-220V 50HZ/ 60HZ ) | |||||||||||
Refrigerant | R22(R407C/ 134a/ 404A/410A) | |||||||||||
Thput power | / Capillary / exernal balance of thermal expansion | |||||||||||
Condenser | High-efficiency copper tube sheathed aluminum fin type + low-noise external rotor fan | |||||||||||
Evaporater | Stainless steel water tank copper evaporator (water tank coil/shell and tube type/stainless steel plate evaporator) | |||||||||||
Security | Compressor overheating protection, overcurrent protection, high and low pressure protection, overtemperature protection, traffic protect ion, phase sequence/phase loss protection, frost |
Note: The temperature range of chilled water outlet is 5-25 ℃, and it is recommended to use it when the ambient temperature is not higher than 35 ℃.
Actual picture of water-cooled chiller
5HP-200HP models are available
Use the installation simple diagram reference
Technical Parameters
Model | GX-3FCS | GX-5FCS | GX-8FCD | GX-10FCD | GX-15FCD | GX-20FCD | GX-30FCS | GX-40FCD | |||
Refrigerating capacity | W | 9000 | 15000 | 24000 | 3000 | 45000 | 60000 | 90000 | 12000 | ||
Compressor power | KW | 2.2 | 3.7 | 6 | 7.5 | 11 | 15 | 22 | 30 | ||
Frozen warer pump power | HP | 0.5 | 0.5 | 1 | 1 | 2 | 3 | 3HP | 5HP | ||
Cooiling warer fiow | L/min | 100 | 100 | 200 | 200 | 340 | 520 | 520 | 800 | ||
Water pump head | m | 18 | 18 | 18 | 18 | 18 | 18 | 20 | 20 | ||
Chilled water pipe | 寸 | 1 | 1 | 1 | 1.5 | 2 | 2 | 2.5 | 2.5 | ||
Tank capacity | L | 54 | 54 | 156 | 156 | 180 | 260 | 280 | 460 | ||
Net weight | Kg | 130 | 145 | 260 | 300 | 360 | 450 | 580 | 860 | ||
Outline dimensions | L*W*H(mm) | 910*550*1000 | 910*550*1000 | 1250*700*1300 | 1250*700*1300 | 1650*800*1450 | 1750*770*1580 | 1750*780*1600 | 2400*900*1800 | ||
lnput power | 3P-380V( 415-50HZ / 60HZ ; 3PH-220V 50HZ/ 60HZ ) | ||||||||||
Refrigerant | R22(R407C/ 134a/ 404A/410A) | ||||||||||
Thput power | Capillary / exernal balance of thermal expansion | ||||||||||
Condenser | Straight tube copper condenser | ||||||||||
Evaporater | Stainless steel water tank copper evaporator (water tank coil/shell and tube type/stainless steel plate evaporator) | ||||||||||
Security | Compressor overheating protection, overcurrent protection, high and low pressure protection, overtemperature protection, traffic protect ion, phase sequence/phase loss protection, frost |
Note: The temperature range of chilled water outlet is 5-25 ℃, and it is recommended to use it when the ambient temperature is not higher than 35 ℃.
Water-cooled screw chiller
An additional cooling tower is required to dissipate heat from the condenser
Comes with a built-in fan to dissipate heat from the chiller, suitable for environments with good ventilation
Parameter table of screw chiller
Model | unit | GXS -30LG | GXS-40LG | GXS -50LG | GXS -60LG | GXS-70LG | GXS-100LG | GXS-120LG | |
standard rating | Kca/h | . 100909 | 137587 | 180551 | 196566 | 262949 | 327438 | 387794 | |
KW | 117.21 | 159.8 | 209.7 | 228.3 | 305.4 | 380.3 | 450.4 | ||
Total input power | KW | 25.2 | 33.1 | 41.5 | 45.5 | 60.2 | 71.2 | 85.5 | |
Maximum operating ammeter | A | 42.1 | 55.4 | 69.4 | 76.1 | 101 | 119.5 | 143.4 | |
power supply | 3PH-380V 50HZ(200V/220V/415V 460V 50HZ/60HZ) | ||||||||
refrigerant | Name | R22(R407C) | |||||||
Charge | KG | 22 | 28 | 33 | 39 | 45 | 55 | 66 | |
Control mode | Outside balance thermai expansion valve | ||||||||
compressor | Type | Semi-hermetic screw | |||||||
power | KW | 24.9 | 32.8 | 41.2 | 45.2 | 59.9 | 70.9 | 85.2 | |
start mode | Y-O | ||||||||
Operating current | A | 41.9 | 55.2 | 69.2 | 75.9 | 100.7 | 119.3 | 143.2 | |
Energy regulation range | % | 0-33%-66%-10% | 0-25%-50%-75%-100% | ||||||
Evaporator | Type | Shell and tube type with internal thread | |||||||
Frozen water volume | m³/h | 21 | 26 | 30 | 43 | 48 | 55 | 68 | |
Heat exchange | KW | 117.2 | 159.8 | 209.7 | 228.3 | 305.4 | 380.3 | 450.4 | |
condenser | Type | External threaded shell and tube type | |||||||
Frozen water volume | m³/h | 26 | 33 | 40 | 50 | 61 | 69 | 85 | |
Heat exchange | KW | 140.6 | 191.7 | 251.6 | 273.9 | 366.4 | 456.3 | 540.4 | |
Diameter of inlet and outlet water pipes | MM | 80 | 80 | 80 | 80 | 100 | 100 | 125 | |
Safety protection device | Compressor overheating protection, aluminum overload protection. High and low pressure protection device, antifreeze protection device, power reverse/phase loss protection source, water flow switch |
||||||||
Measure | Length (mm) | MM | 1960 | 2130 | 2450 | 3100 | 3500 | 3500 | 3750 |
Width (mm) | MM | 855 | 855 | 985 | 1050 | 1050 | 1050 | 1050 | |
Height (m) | MM | 1540 | 1540 | 1600 | 1600 | 1600 | 1600 | 1730 | |
Weight | KG | 820 | 950 | 1120 | 1300 | 1560 | 1560 | 2030 |
A corner of the production workshop